COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S17
3. ACTIVE TEST AND UTILITY
The 8 items below are used (Security level 2 or higher required).
9Y3200007CRS0018US0
(Operating conditions → specified tool conditions)
1. The conditions below are required for "Injector non-injection instruction" and "Supply pump learning".
• Machine is stopped
• Neutral switch is ON
9Y3200007CRS0019US0
1 Injector non-injection instruction
From the active test screen
2 EGR actuation test
3 Glow relay actuation test
4 Intake throttle valve actuation test
5 NCD check function
6 Supply pump learning (clear the learning value)
From the utility screen7HMI for PCD