COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S49
(7) Poor Acceleration (Insufficient Output)
Possible causes:
1. Fuel feed pump operation fault.
2. Large driving resistance due to problems in the machine itself that do not involve the engine
Large resistance for actuation
Tire air pressure
Power transmission fault
Brake drag
*Refer to the previous "List of malfunction causes by symptom" for the subsequent details.
3. Engine fault
Low compression pressure.
Engine internal fault
Valve clearance fault
Valve timing fault
Engine oil viscosity fault
4. Control system
Damage to the pulsar gear of the crankshaft position sensor
Air gap of the crankshaft position sensor is large
Accelerator position sensor misadjustment
SCV operation fault
5. Intake system
Air cleaner clogging
Leak from the intake system parts
Turbocharger operation fault
6. Fuel system
Supply pump learning has not been performed
Fuel quality
Fuel pressure limiter fault
Fuel line clogging, leak
7. CRS (including related parts)
Output system (supply pump, injector and common rail)
Input system (sensors) *A cause for larger injection quantity
•Engine ECU
8. Others
Power transmission fault
Large amount of drag (including the brakes, etc.)
Defective CAN communication
9Y3200007CRS0070US0
1. Check the Fuel Feed Pump Operation
1. Turn the key switch ON and check that the fuel feed pump is
operating.
9Y3200007CRS0027US0
Service
specification
Operates when the key switch is turned ON.
OK Go to "2. Check the DTC".
NG Check in accordance with "6.[2] FUEL SYSTEM INSPECTION
PROCEDURE - 5. Check the Fuel Feed Pump". (Refer to page 1-S324)
(1) Fuel Feed Pump
KiSC issued 03, 2022 A