EasyManua.ls Logo

Kubota 07-CR-E5 - Sensor Supply Voltage 2 Abnormality (DTC P0652; 3510-4, P0653; 3510-3)

Kubota 07-CR-E5
373 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S229
(33) Sensor Supply Voltage 2 Abnormality (DTC P0652 / 3510-4, P0653 /
3510-3)
P0652 / 3510-4: Sensor supply voltage 2: Low
Behaviour during malfunction:
Faulty starting
Insufficient output
Worsening exhaust gas performance
Detection item:
Sensor supply voltage 2 error or recognition error
DTC set preconditions:
Battery voltage is normal
Key switch turn ON
Starter Switch signal (Engine ECU: V12 terminal) is not activated
DTC set parameter:
Voltage to sensor is below 4.375 V
Engine warning light:
•ON
Limp home action by engine ECU (system action):
Output limitation: Approximately 75 % of normal condition
Recovery from error:
Key switch turn OFF
9Y3200007CRS0348US0
P0653 / 3510-3: Sensor supply voltage 2: High
Behaviour during malfunction:
Faulty starting
Insufficient output
Worsening exhaust gas performance
Detection item:
Sensor supply voltage 2 error or recognition error
DTC set preconditions:
Battery voltage is normal
Key switch turn ON
Starter Switch signal (Engine ECU: V12 terminal) is not activated
DTC set parameter:
Voltage to sensor is above 5.625 V
Engine warning light:
•ON
Limp home action by engine ECU (system action):
Output limitation: Approximately 75 % of normal condition
Recovery from error:
Key switch turn OFF
9Y3200007CRS0349US0
KiSC issued 03, 2022 A