Kubota 07-CR-E5 - Battery Voltage Abnormality (DTC P0562; 168-4, P0563; 168-3)

Kubota 07-CR-E5
373 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S215
(27) Battery Voltage Abnormality (DTC P0562 / 168-4, P0563 / 168-3)
P0562 / 168-4: Battery voltage: Low
Behaviour during malfunction:
Faulty starting
Insufficient output
Worsening exhaust gas performance
Engine stops in some case
Detection item:
Open circuit, short circuit or damage of harness
Failure of battery
DTC set preconditions:
Key switch is ON
Starter Switch signal (Engine ECU: V12 terminal) is not activated
DTC set parameter:
Engine ECU recognition of battery voltage is below 8 V in 12 V system
Not monitored during cranking
Engine warning light:
•ON
Limp home action by engine ECU (system action):
Output limitation: Approximately 75 % of normal condition
EGR stop
Intake throttle 100 % open
Recovery from error:
Diagnostic counter = zero or Key switch turn OFF
9Y3200007CRS0319US0
P0563 / 168-3: Battery voltage: High
Behaviour during malfunction:
Faulty starting
Insufficient output
Worsening exhaust gas performance
Detection item:
Open circuit, short circuit or damage of harness
Failure of battery
DTC set preconditions:
Key switch is ON
Starter Switch signal (Engine ECU: V12 terminal) is not activated
DTC set parameter:
Engine ECU recognition of battery voltage is above 16 V in 12 V system
Engine warning light:
•ON
Limp home action by engine ECU (system action):
Output limitation: Approximately 75 % of normal condition
EGR stop
Intake throttle 100 % open
Recovery from error:
Key switch turn OFF
9Y3200007CRS0320US0
KiSC issued 03, 2022 A