COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S299
(60) Excessive PM5 (DTC P3008 / 3701-0)
Behaviour during malfunction:
Insufficient output
Detection item:
PM accumulation level 5
DTC set preconditions:
Battery voltage is normal
DTC set parameter:
PM accumulation more than trigger level
Regeneration level = 5
Engine warning light:
•ON
Limp home action by engine ECU (system action):
Output limitation: Approximately 50 % of normal condition
Recovery from error:
Key switch turn OFF (Reset by Service tool)
9Y3200007CRS0467US0
1. Replace the DPF
1. Replace the DPF.
NOTE
Followings are potential causes.
A manual regeneration has not been carried out.
9Y3200007CRS0468US0
(1) DPF Outlet Body
(2) DPF Filter Comp
(3) DOC Catalyst
(4) DPF Gasket
(5) DPF Gasket
KiSC issued 03, 2022 A