EasyManua.ls Logo

Kubota 07-CR-E5 - Fuel Temperature Sensor Abnormality (DTC P0182; 174-4, P0183; 174-3)

Kubota 07-CR-E5
373 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S172
(13) Fuel Temperature Sensor Abnormality (DTC P0182 / 174-4, P0183 / 174-3)
P0182 / 174-4: Fuel temperature sensor: Low
Behaviour during malfunction:
None
Detection item:
Ground short circuit of sensor / harness
DTC set preconditions:
Battery voltage is normal
DTC set parameter:
Voltage of temperature sensor in supply pump is 0.1 V or less
Engine warning light:
•ON
Limp home action by engine ECU (system action):
During start-up = 20 °C (4 °F) [default value]
Under other conditions = 45 °C (113 °F) [default value]
Output limitation: Approximately 75 % of normal condition
Recovery from error:
Diagnostic counter = zero or Key switch turn OFF
9Y3200007CRS0225US0
P0183 / 174-3: Fuel temperature sensor: High
Behaviour during malfunction:
None
Detection item:
Open circuit or +B short circuit of sensor / harness
DTC set preconditions:
Battery voltage is normal
DTC set parameter:
Voltage of temperature sensor in supply pump is 4.9 V or above
Engine warning light:
•ON
Limp home action by engine ECU (system action):
During start-up = 20 °C (4 °F) [default value]
Under other conditions = 45 °C (113 °F) [default value]
Output limitation: Approximately 75 % of normal condition
Recovery from error:
Diagnostic counter = zero or Key switch turn OFF
9Y3200007CRS0226US0
KiSC issued 03, 2022 A

Table of Contents

Related product manuals