(12) Fuel High Temperature (DTC P0181 / 174-0)
Behaviour during malfunction:
•None
Detection item:
Fuel temperature high
DTC set preconditions:
Passed 300 sec. after cranking
Engine speed is 800 min
-1
(rpm) or more
Fuel temperature sensor is normal
DTC set parameter:
Fuel temperature higher than 90 °C (194 °F)
Engine warning light:
•ON
Limp home action by engine ECU (system action):
Output limitation: Approximately 75 % of normal condition
Recovery from error:
Diagnostic counter = zero or Key switch turn OFF
9Y3200007CRS0222US0
1. Check the Fuel System
1. Check in accordance with "6.[2] FUEL SYSTEM INSPECTION
PROCEDURE". (Refer to page 1-S321)
NOTE
If the machine has a fuel fooler, check whether the fuel
cooler is installed to the proper position.
Check whether the cooling performance does not decrease
due to dust.
Check whether the fuel pipe is appropriate.
Check the clogging condition of the fuel filter. If it is very
dirty, replace the new one.
9Y3200007CRS0223US0
2. Check the Fuel Temperature Sensor (*Refer to Items P0182
and P0183)
1. Check the fuel temperature sensor. (Refer to page 1-S172)
9Y3200007CRS0224US0
OK Go to "2. Check the Fuel Temperature sensor (Refer to items P0182 and
P0183)".
NG Repair in accordance with "6.[2] FUEL SYSTEM INSPECTION
PROCEDURE". (Refer to page 1-S321)
(1) Fuel Hose
OK Normal.
NG Replace the SCV or supply pump unit (under warranty). (Or its related
parts. Follow the diagnostic procedure of items P0182 and P0183.)
(Refer to page 1-S172)