COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S124
9Y3200007CRS0160US0
Name
Low coolant temperature in parked
regeneration
Parked regeneration time out
ISO 14229
P-Code
P3012 P3013
J1939-73
SPN 523589 523590
FMI 17 16
SPN Name
SAE J1939 Table C1
proprietary proprietary
DTC Name
Low coolant temperature in parked
regeneration
Parked regeneration time out
Detection item
• During regeneration mode, engine
warm-up condition is not satisfied
(coolant temperature is low)
• Time out error: regeneration incomplete
due to low temperature of DPF
DTC Set
Preconditions
• During parked active regeneration mode • During parked active regeneration mode
• Coolant temperature is 50 °C (122 °F) or
more
DTC set parameter
• Engine coolant temperature stays below
50 °C (122 °F) for 1500 seconds or more
under parked regeneration process
• Regeneration process is not completed
within 2700 sec.
Time to action or
number of error
detection
• Transient • Transient
Limp Home Action
by engine ECU
(system action)
•None •None
Behaviour During
Malfunction
•None •None
Engine Warning
Light
•ON •ON
Recovery from
error
• Diagnostic counter = zero
or Key switch turn OFF
(Leaving from parked active
regeneration status)
• Diagnostic counter = zero
or Key switch turn OFF
(Leaving from parked active
regeneration status)
Delay time for
recovery
• Immediately • Immediately
Remark