EasyManua.ls Logo

Kubota 07-CR-E5 - Page 162

Kubota 07-CR-E5
373 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S124
9Y3200007CRS0160US0
Name
Low coolant temperature in parked
regeneration
Parked regeneration time out
ISO 14229
P-Code
P3012 P3013
J1939-73
SPN 523589 523590
FMI 17 16
SPN Name
SAE J1939 Table C1
proprietary proprietary
DTC Name
Low coolant temperature in parked
regeneration
Parked regeneration time out
Detection item
During regeneration mode, engine
warm-up condition is not satisfied
(coolant temperature is low)
Time out error: regeneration incomplete
due to low temperature of DPF
DTC Set
Preconditions
During parked active regeneration mode During parked active regeneration mode
Coolant temperature is 50 °C (122 °F) or
more
DTC set parameter
Engine coolant temperature stays below
50 °C (122 °F) for 1500 seconds or more
under parked regeneration process
Regeneration process is not completed
within 2700 sec.
Time to action or
number of error
detection
Transient Transient
Limp Home Action
by engine ECU
(system action)
•None •None
Behaviour During
Malfunction
•None •None
Engine Warning
Light
•ON •ON
Recovery from
error
Diagnostic counter = zero
or Key switch turn OFF
(Leaving from parked active
regeneration status)
Diagnostic counter = zero
or Key switch turn OFF
(Leaving from parked active
regeneration status)
Delay time for
recovery
Immediately Immediately
Remark
KiSC issued 03, 2022 A

Table of Contents

Related product manuals