COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S7
9Y3200007CRS0009US0
Heat the accelerator sensor and other electrical components with a hair dryer.
Verify whether or not the voltage value (resistance value) changes.
• Do not exceed 60 °C (140 °F) (still touchable by hand) when heating.
• Do not remove the component case and add heat directly to
electronic parts.
––
Verify whether or not malfunction symptoms occur under heavy engine loads
(headlights, A/C, wiper, etc. switches ON).
–
If any commercial electrical products have been installed, remove them and
verify whether or not the malfunction symptoms occur.
If it is thought that the malfunction occurs in rainy or high temperature weather, spray the machine
with water and verify whether or not the malfunction occurs.
• Do not spray water directly onto the engine. Spray water mist on the entire surface of the
radiator to indirectly change the temperature and humidity of the engine compartment.
• Do not spray water directly on electrical parts.
Action
Malfunction symptom
Dead battery
Engine will not
start
Idle speed
abnormal engine
stall sluggish
poor
acceleration