2J0/2J1/2J2
1-5-32
(3) Detaching and refitting the power source unit (PWB)
Procedure
1. Remove the top cover (See page 1-5-3).
2. Remove the right cover (See page 1-5-4).
3. Remove the drum unit (See page 1-5-12).
4. Remove one connector (YC11) from the
connect-L PWB.
5. Remove the wires from the drum grounding
plate and clamp.
6. Release two hooks and then remove the
PSU fan motor.
Figure 1-5-43
Drum grounding
plate
Clamp
Wire
Connector (YC11)
Connect-L PWB
PSU fan motor
Hook
Hook