EasyManua.ls Logo

Kyocera FS-2020D - Detaching and Refitting the Power Source Unit (PWB)

Kyocera FS-2020D
135 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2J0/2J1/2J2
1-5-32
(3) Detaching and refitting the power source unit (PWB)
Procedure
1. Remove the top cover (See page 1-5-3).
2. Remove the right cover (See page 1-5-4).
3. Remove the drum unit (See page 1-5-12).
4. Remove one connector (YC11) from the
connect-L PWB.
5. Remove the wires from the drum grounding
plate and clamp.
6. Release two hooks and then remove the
PSU fan motor.
Figure 1-5-43
Drum grounding
plate
Clamp
Wire
Connector (YC11)
Connect-L PWB
PSU fan motor
Hook
Hook