2MY/2MZ
1-3-61
U161 Setting the fuser control temperature
Description
Changes the fuser control temperature and control temperature correction value and other set 
values.
Purpose
Normally no change is necessary. However, this mode can be used to prevent curling or creasing 
of paper, or solve a fuser problem on thick paper.
Setting
1. Press the start key.
2. Select the item to be set.
3. Change the setting value using the cursor left/right keys.
4. Press the start key. The value is set.
Item No. Description
Display Description
Setting
range
Initial
setting
20ppm 25ppm
Copy 
Curb(Edge)
Prevention temperature of overtem-
perature rise under copy
100 to 250 210 210
Curb(Edge) Prevention temperature of overtem-
perature rise
100 to 250 240 240
Return(Edge) Return temperature of overtempera-
ture rise
100 to 250 190 190
Ready(Edge) Ready display temperature 0 to 200 95 100
Pressure(Press) Pressurizing beginning temperature 0 to 200 85 90
High 
speed(Center)
Full speed shift temperature 0 to 200 110 115
Ready(Center) Ready display temperature 100 to 200 135 140
Drive(Center) The second stability temperature 100 to 200 140 145
Full speed(Cen-
ter)
Print control temperature 100 to 200 140 145
Wait(Center) Control temperature when being 
standing by
100 to 200 115 120
WarmUp 
Curb(Center)
Electric power control temperature 
at start-up
0 to 200 135 140
Curb(Center) Prevention temperature of overtem-
perature rise
170 to 250 240 240
Low power(Cen-
ter)
Low electric power control 
temperature
0 to 200 85 90
Ready(Press) Ready display temperature 0 to 200 40 45
Curb(Press) Prevention temperature of overtem-
perature rise
170 to 250 200 200
Wait Off-
set(Press)
Correction temperature when being 
standing by
0 to 200 85 90