2MY/2MZ
1-3-51
U107 Setting the voltage for the intermediate transfer cleaning 
Description
Sets the control voltage for the intermediate transfer cleaning.
Purpose
To change the setting when the offset by a defective cleaning of the transfer belt is generate.
Method
1. Press the start key.
2. Select the item. The screen for executing each item is displayed.
Setting
1. Select the item to be set.
2. Change the setting value using the cursor left/right keys or numeric keys.
3. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
Belt(A)
Correction value of belt A
Belt(B)
Correction value of belt B
Belt(C)
Correction value of belt C
Display Description
Setting 
range
Initial setting
20ppm 25ppm
Full
Full speed printing of color 0 to 200
10/72/72 13/90/90
Half
Half speed printing of color 0 to 200
9/45/45 9/45/45
3/4 75% of full speed printing of color
0 to 200
9/54/72 10/68/90
B/W Full Full speed printing of monochrome
0 to 200
10/60/60 13/90/90
B/W Half Half speed printing of monochrome
0 to 200
9/42/42 9/68/68
B/W 3/4 75% of full speed printing of 
monochrome
0 to 200
9/35/35 10/45/45