2MY/2MZ
1-6-2
Emergency-UPDATE
If the device is accidentally switched off and upgrading was incomplete, upgrade becomes impossible from a 
USB flash device.
In that case, retry upgrading after recovering the software by following the procedure below.
Preparation
The CF memory card must be formatted in FAT or FAT32 in advance.
Extract the main firmware to download from the file.
Rename the file which was extracted from the archive. [DL_CTRL.2MY] to [KM_EMRG.2MY]
Copy the all extracted files to the root of the CF memory.
Procedure
1. Turn the main power switch off.
2. Install the CF memory card which con-
tains the firmware onto the main PWB.
3. Turn the main power switch on.
4. Rewriting of the PWB software will start 
for restoration.
The memory and attention LEDs will be 
blinking.
5. Only the Memory LED will be blinking 
when rewriting is successful.
* : Only the Attention LED will be blinking 
when rewriting is failed.
6. Turn the main power switch off.
7. Wait for several seconds and then 
remove the CF memory from the main 
PWB.
8. Extract the firmware to download from 
the archive and copy to the root of the 
USB flash device.
NOTE: Deletes the "ES_SKIP.on" file 
When it is contained directly under the 
USB memory.
Figure 1-6-2
9. Insert the USB flash device in which the 
firmware was copied into the slot on the 
machine.
10. Perform steps 3 to 8 on the previous 
page.
11. Turn the main power switch on.
12. Perform maintenance item U000 (Print 
a maintenance report) to check that the 
version of ROM U109 has been 
upgraded.
CF memory
CF memory
socket