2MY/2MZ-3
2-4-22
When maintenance item U411 (Automatic adjustment in the scanner) is run using the specified original (P/N 7505000005), 
the following adjustments are automatically made: 
Adjusting the scanner magnification (U065) 
Adjusting the scanner leading edge registration (U066) 
Adjusting the scanner center line (U067) 
When maintenance item U411 (Automatic adjustment in the DP) is run using the specified original (P/N 302AC68243),
 the following adjustments are automatically made: 
* : When running this test chart, you first must clean the feed rollers with alcohol and ensure the DP width guides 
are correctly positioned against the original.
Adjusting the DP magnification (U070) 
Adjusting the DP leading edge registration (U071) 
Adjusting the DP center line (U072) 
11
Adjusting magnification of the 
scanner in the auxiliary scanning 
direction 
(scanning adjustment)
Original scanning speed U065
U070
X SCAN ZOOM
X SCAN ZOOM
Test chart P.1-3-31
P.1-3-37
U065: For copying an original placed on 
the platen.
U070: For copying originals from the DP.
12
Adjusting the center line 
(scanning adjustment)
Adjusting the original scan data
(image adjustment)
U067
U072
FRONT
ROTATE
FRONT
BACK
Test chart P.1-3-34
P.1-3-40
U067: For copying an original placed on 
the platen.
To make an adjustment for rotate copying, select 
ROTATE.
U072: For copying originals from the DP.
To make an adjustment for duplex copying, select 
BACK.
13
Adjusting the leading edge registra-
tion 
(scanning adjustment)
Original scan start timing U066
U071
FRONT
ROTATE
FRONT HEAD
BACK HEAD
Test chart P.1-3-33
P.1-3-38
U066: For copying an original placed on 
the platen.
To make an adjustment for trailing edge registra-
tion, select ROTATE.
U071: For copying originals from the DP.
To make an adjustment for duplex copying, select 
BACK HEAD.
14
Adjusting the leading edge margin 
(scanning adjustment)
Adjusting the original scan data
(image adjustment)
U403
U404
B MARGIN
B MARGIN
Test chart P.1-3-78
P.1-3-79
U403: For copying an original placed on 
the contact glass
U404: For copying originals from the DP.
15
Adjusting the trailing edge margin 
(scanning adjustment)
Adjusting the original scan data
(image adjustment)
U403
U404
D MARGIN
D MARGIN
Test chart P.1-3-78
P.1-3-79
U403: For copying an original placed on 
the contact glass
U404: For copying originals from the DP.
16
Adjusting the left and right margins 
(scanning adjustment)
Adjusting the original scan data
(image adjustment)
U403
U404
A MARGIN
C MARGIN
A MARGIN
C MARGIN
Test chart P.1-3-78
P.1-3-79
U403
: For copying an original placed on 
the contact glass
U404: For copying originals from the DP.
Adjusting 
order
Item Image Description
Maintenance mode
Original Page Remarks
Item No. Mode
Image quality