8-4 Test and Adjustment
D-I012.1109EN
innovators in agriculture
6. If the charging current is less than 1.0 A, make sure the orange LED
on the charging station is ON.
7. If not, make sure the main power is connected to the battery
charger.
8. If the JUNO 150 is still not charging, make sure the electrodes are
connected to the battery charger.
9. If the JUNO 150 is still not charging, clean the charging strips and
the electrodes (page 7-4).
10. If the JUNO 150 is still not charging, make sure all power
connections are connected properly.
11. If the JUNO 150 is still not charging, call the local service provider.
Figure 49. Battery charging current
8.3.5 Test the Ultrasonic Sensor
Test
1. Manually drive the JUNO 150 to a location more than 6 m (6.6 yrd)
from a wall.
2. Make sure no object is between the ultrasonic sensor and the wall.
3. In the main menu of the E-Link select Test and push [ ].
4. Select Ultrasound and push [ ].
5. If the ultrasonic sensor is on the left, push soft button [L], else push
[R].
6. Make sure the JUNO 150 is between you and the wall.
Note:
Make sure not to interrupt the sensing beam.
7. Monitor the E-Link display.
8. Make sure the Puls 1, Puls 2, Puls 3 and Filter values are 0.
9. If the values are not 0, clean the ultrasonic sensor with a tissue.
10. Repeat the steps 7 and 8.
11. If the values are not 0, call your local Lely service provider.
12. If the puls and filter values are 0,
1. Put an object exactly 1 m. (1.1 yrd) from the ultrasonic sensor.
2. Make sure the Puls 1 and Filter show 1000 (mm).
Else call your local service provider.