9-8 Troubleshooting
D-I012.1109EN
innovators in agriculture
9.2.3 Read a Report
1. Get the E-Link Manual Controller (page 6-2).
2. Push [ESC] or [
] to wake up the E-Link.
3. Stop all timed actions (page 6-13).
4. In the main menu of the E-Link, select Alarms and push [
].
5. Select Report list and push [
] .
The display display the number, the date and time the report was
recorded and the report number, like in the following example:
No. Date Time Rep
1 4-1 20:10 6
2 4-1 21:31 15
Note:
Select a report in the list and push [
] to open the report message for extra
information.
6. Note the report number and look it up in the report list.
7. Do the indicated procedure.
9.2.4 Report List
The table below gives the report numbers and any actions to be taken:
Report
code
Report Description/Procedure
1 Timepath contains x % drive time The JUNO 150 must not drive more than 40%
of the total time in a time path. It must spend
minimum 60% of the total time charging at the
charge station.
2 Left chain is slack. Check chain tension
1. Make sure the chain can move 5 mm up
and down.
2. If not, tighten the chain (page 7-6).
3 Right chain is slack. Check chain tension
1. Make sure the chain can move 5 mm up
and down.
2. If not, tighten the chain (page 7-6).
4 Left tire has a smaller diameter. Route less
reliable!!
1. Call your local Lely service provider.
5 Right tire has a smaller diameter. Route less
reliable!!
1. Call your local Lely service provider.
6 Drive distance increases Check skid. Route
less reliable!!
1. Make sure the floor is not slippery.
2. Make sure the JUNO 150 does not skid.
7 Ultrasound sensor gives too many reflec
Check startpulse
Clean ultrason sensor
Install cover correct
1. Clean the ultrasound sensor.
2. Make sure the cover does not cover the
sensor.
3. If the problem remains, call your local Lely
service provider.