Troubleshooting 9-9
D-I012.1109EN
innovators in agriculture
Report
code
Report Description/Procedure
8 Ultrasound sensor gives too many reflec
Check startpulse
Clean ultrason sensor
Install cover correct
1. Clean the ultrasound sensor
2. Make sure the cover does not cover the
sensor.
3. If the problem remains, call your local Lely
service provider.
9 Left motor drives harder than the right
motor ->check the drive and the motor
1. Call your local Lely service provider.
10 Right motor drives harder than the right
motor ->check the drive and the motor
1. Call your local Lely service provider.
11 Low charging current!
-Clean chargingstrips
-Check charger
1. Manually drive the JUNO 150 to the
charging station (page 6-4).
2. Clean the charging strips and the charging
electrodes (page 7-4).
Make sure the battery is charging (page 8-3).
12 The charging current is too low, check
connection points and power
Refer to report 11.
13 Battery condition bad Install a new battery
1. Install a new battery.
14 Battery is overloaded too many times See
battery yield and check battery and capacity
Vehicle drives back 2 m automatically to
protect the battery.
1. Call your local Lely service provider.
15 "Battery power too low to start route,
charge first! "
1. Clean the charging strips and the charging
electrodes (page 7-4).
2. Charge the JUNO 150.
16 Battery power too low to start route! Drive
JUNO 150 to charger or clean charge strips!
1. Clean the charging strips and the charging
electrodes (page 7-4).
2. Charge the JUNO 150.
17 JUNO 150 is not finished with test route.
Please switch on the route.
1. Call your local Lely service provider.
18 Battery condition deteriorates. Check
battery
1. Call your local Lely service provider.
19 The current of the batt is low when the
JUNO 150 drives
1. Call your local Lely service provider.
20 Bad signal of:
- ultrasound sensor
1. Clean the ultrasonic sensor.
21 Route is not correct
- unreliable
- see route analysis
- see manual
1. Analyse the route and make a more
reliable route if necessary (page 8-2).
34 Battery is charged The charge cyclus is
complete
For information only.
50 - 55 Battery is overloaded too many times See
battery yield and check battery and capacity
1. Call your local Lely service provider.
60 Ultrasound sensor gives too many reflec
Check startpulse
1. Clean the ultrasonic sensor.
2. Test the ultrasonic sensor (page 8-4).