Symptom Possible cause Action
The backup process of the
routes does not function
The software version of the E-Link
is not correct
1. Make sure software version of
the E-Link is 1.07 or newer
(version is displayed on the
E-Link start up screen when
you reset the E-Link). If the
version is not correct:
Call your local Lely service
provider.
9.3.2 Troubleshooting Table JUNO 150 Charging Station
Symptom Possible cause Action
Green and Yellow LED
together blink 2 times,
followed by a few seconds
rest
Battery loader defect Call your local Lely service provider.
Temperature lower than - 15
degrees C (5 degrees F)
Warm the barn and try again. Green and Yellow LED
together blink 4 times,
followed by a few seconds
rest
Battery loader defect Call your local Lely service provider.
Green and Yellow LED
together blink 5 times,
followed by a few seconds
rest
Internal temperature is higher
than 85 degrees C (185 degrees F)
Remove plug from the mains.
Connect plug and retry after one
hour.
Green and Yellow LED
together blink 7 times,
followed by a few seconds
rest
Current too high (>20 A). Remove short-circuit, else:
Call your local Lely service provider.