5-10 Installation
D-I012.1109EN
innovators in agriculture
5. Make sure the battery charger mounting plate is correctly installed
(page 5-7).
6. Make sure no wiring is pinched off.
7. Lower the cover until the stop.
Figure 30. Install the cover
5.4.7 Install the Inductive Metal Guiding Strips
Parts
3× Metal guiding strip
12× Split nail 6x35 mm.
Installation
1. Put the metal strips (1, fig. 31, page 5-11), (2) and (3) on the floor.
2. Make sure the distance between the strips and the wall is 79 cm
(31.1 in.).
3. Make sure the distance between the end of the last strip and the
charger electrode is 100 cm (39.4 in.).
4. Make sure the angle between the left strip and the other strips is 45
degrees.
5. Install the metal strips on the floor with the twelve split nails.