EasyManua.ls Logo

Lenovo System x3250 M5 - Page 178

Lenovo System x3250 M5
740 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Readthesafetyinformationin“Safety”onpagevand“Installationguidelines”onpage31.
Ifyouarereplacingaservercomponentintheserver,youneedtoslidetheserveroutfromtherack
enclosure,turnofftheserverandperipheraldevices,anddisconnectthepowercordsandallexternalcables.
ToreplacethePCIriser-cardassembly,completethefollowingsteps.
Step1.InstalltheadapterinthePCIriser-cardassembly(see“Replacinganadapter”onpage185or
“ReplacinganLenovoServeRAIDSAS/SATAcontrolleronpage188).
Step2.ReconnectanyadaptercablesthatyoudisconnectedwhenyouremovedthePCIriser-card
assembly.
Step3.CarefullyalignthePCIriser-cardassemblywiththeguidesontherearoftheserverandwiththe
PCIriser-cardconnectoronthesystemboard;then,placeyourthumbsonlocationsmarkedbythe
bluetabsandpressdownonthePCIriser-cardassembly.Makesurethattheriser-cardassembly
isfullyseatedintheconnectoronthesystemboard.
0000000
0000000
0000000
0000000
0000000
Figure92.PCIriser-cardassemblyinstallation
Step4.Reinstallthecover(see“Replacingthecover”onpage158).
Whattodonext
1.Installtheserverintotherackenclosureandpushtheserverintotherackuntilitclicksintoplace.
2.Reconnectthepowercordsandanycablesthatyouremoved.
3.Turnontheperipheraldevicesandtheserver.
RemovingtheRAIDadapterbatteryorflashpowermoduleholder
UsethisinformationtoreplacetheRAIDadapterbatteryorflashpowermoduleholderintheserver.
Note:RAIDadapterbatteryorflashpowermoduleholderisonlysupportedinthe2.5-inchmodels.
164LenovoSystemx3250M5InstallationandServiceGuide

Table of Contents

Other manuals for Lenovo System x3250 M5

Related product manuals