Loading...
Ifyouarereplacingaservercomponentintheserver,youneedtoslidetheserveroutfromtherack
enclosure,turnofftheserverandperipheraldevices,anddisconnectthepowercordsandallexternalcables.
ToreplaceaRAIDadapterbatteryorflashpowermoduleintheserver,completethefollowingsteps:
Step1.Installthebatteryorflashpowermodule:
a.Removetheretainer.
b.Releasetheretentionclipintheopenposition.
c.Alignthecableconnectorwiththeslotontheholder.Placethebatteryorflashpowermodule
intotheholderandmakesurethattheholderengagesthebatteryorflashpowermodule
securely.
000000
000000
000000
000000
000000
Figure126.RAIDadapterbatteryorflashpowermoduleinstallation
Note:Thepositioningoftheremotebatteryorflashpowermoduledependsonthetypeof
theremotebatteriesorflashpowermodulesthatyouinstall.
d.Connecttheotherendofthecabletothecableconnectoronthebatteryorflashpower
module.
e.Lowerandpressdownontheretentionclipuntilitsnapsinplacetoholdthebatteryorflash
powermodulefirmlyinplace.
f.Installtheretainerthatyouremoved.
g.Installtheretainer.
Step2.Reinstallthecover(see“Replacingthecover”onpage158).