3.CheckLenovosupportsiteforanyapplicableservicebulletinorUEFIoradapterfirmware
updatethatappliestothiserror.NOTE:ItmaybenecessarytoconfigureslottoGen1ortouse
specialutilitysoftwaresothatadapterfirmwarecanbeupgraded.Gen1/Gen2settingscanbe
configuredviaF1Setup->SystemSettings->DevicesandI/OPorts->PCIeGen1/Gen2/Gen3
SpeedSelection,ortheToolsCenterSuiteCLIUtility.
4.Replacetheadapter.
I.3808004TheIMMSystemEventlog(SEL)isfull.IPMISystemEventLogisFull
Explanation:
Severity
Info
UserResponse
Completethefollowingsteps:
1.UsetheIMMWebInterfacetocleartheeventlog.
2.IfIMMcommunicationisunavailable,useF1SetuptoaccessSystemEventLogsMenuand
ChooseClearIMMSystemEventLogandRestartServer.
I.3818001Thefirmwareimagecapsulesignatureforthecurrentlybootedflashbankisinvalid.
CurrentBankCRTMCapsuleUpdateSignatureInvalid
Explanation:
Severity
Info
UserResponse
Completethefollowingsteps:
1.Rebootthesystem.WillcomeuponbackupUEFIimage.UpdatetheprimaryUEFIimage.
2.Iferrordoesnotpersistnoadditionalrecoveryactionisrequired.
3.Iferrorpersists,orbootisunsuccessful,(Trainedservicetechnicianonly)Replacethesystem
board.
I.3818002Thefirmwareimagecapsulesignatureforthenon-bootedflashbankisinvalid.Opposite
BankCRTMCapsuleUpdateSignatureInvalid
Explanation:
Severity
Info
UserResponse
Completethefollowingsteps:
1.UpdatethebackupUEFIimage.
2.Iferrordoesnotpersistnoadditionalrecoveryactionisrequired.
3.Iferrorpersists,orbootisunsuccessful,(Trainedservicetechnicianonly)Replacethesystem
board.