Step1.Carefullyturntheserveronitssidesothatitislyingflat,withthecoverfacingup.
Attention:Donotallowtheservertofallover.
Step2.Unlockandremovetheleft-sidecover(see“Removingtheleft-sidecover”onpage182).
Step3.Removetheairbaffle(see“Removingtheairbaffle”onpage188).
Step4.Disconnectthefancagepowercablefromthesystemboard(see“Internalcableroutingand
connectors”onpage33).
Step5.Rotatethefancagereleaselatchtotheopenposition.
0
00
00
0
0
0
0
0
00
00
00
1
2
Fan cage assembly
Figure180.Fancageremoval
Step6.Graspthefancageassemblyandliftitoutoftheserver.
Ifyouareinstructedtoreturntheservercomponentoroptionaldevice,followallpackaginginstructions,
anduseanypackagingmaterialsforshippingthataresuppliedtoyou.
Installingthefancageassembly
Usethisinformationtoinstallthefancageassemblyfromtheserver.
Attention:Makesurethatallwiresandcablesinsidetheserverareroutedcorrectlybeforeyouinstall
thefancageassembly.Wiringthatisnotproperlyroutedmightbedamagedormightpreventthefan
cageassemblyfromseatingproperlyintheserver.
Readthesafetyinformationin“Safety”onpagev
and“Installationguidelines”onpage29.
Ifyouarereplacingaservercomponentintheserver,youneedtoturnofftheserverandperipheraldevices,
anddisconnectthepowercordsandallexternalcables.
Toinstallthefancageassembly,completethefollowingsteps.
Step1.Carefullyturntheserveronitssidesothatitislyingflat,withthecoverfacingup.
262Systemx3500M5InstallationandServiceGuide