EasyManua.ls Logo

Lenovo System x3500 M5 Type 5464 - IMM Events that Automatically Notify Support

Lenovo System x3500 M5 Type 5464
1236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ProvidestheprefixofthemessageIDandthesequencenumberthatisusedbytheCIMmessage
registry.
SNMPTrapID
TheSNMPtrapIDthatisfoundintheSNMPalertmanagementinformationbase(MIB).
AutomaticallycontactService
IfthisfieldissettoY es,andyouhaveenabledElectronicServiceAgent(ESA),Supportwillbenotified
automaticallyiftheeventisgenerated.
WhileyouwaitforSupporttocall,youcanperformtherecommendedactionsfortheevent.
Userresponse
Indicateswhatactionsyoushouldperformtosolvetheevent.
Performthestepslistedinthissectionintheordershownuntiltheproblemissolved.Afteryouperform
alloftheactionsthataredescribedinthisfield,ifyoucannotsolvetheproblem,contactSupport.
Note:Thislistincludeserrorcodesandmessagesthatmightnotapplytothismachinetypeandmodel.
ThefollowingisthelistofIMM2.1errormessagesandsuggestedactionstocorrectthedetectedserver
problems.FormoreinformationaboutIMM2.1,seetheIntegratedManagementModuleIIUser'sGuide
athttp://publib.boulder.ibm.com/infocenter/systemx/documentation/topic/com.lenovo.sysx.imm2.doc/
printable_doc.html.
IMMEventsthatautomaticallynotifySupport
YoucanconfiguretheIntegratedManagementModuleII(IMM2)toautomaticallynotifySupport(alsoknown
ascallhome)ifcertaintypesoferrorsareencountered.Ifyouhaveconfiguredthisfunction,seethetablefor
alistofeventsthatautomaticallynotifySupport.
Table39.EventsthatautomaticallynotifySupport
EventIDMessageString
Automatically
NotifySupport
40000086-00000000
TestCallHomeGeneratedbyuser[arg1].()
Yes
40000087-00000000
ManualCallHomebyuser[arg1]:[arg2].()
Yes
80010202-0701xxxx
Numericsensor[NumericSensorElementName]goinglow
(lowercritical)hasasserted.(CMOSBattery)
Yes
80010902-0701xxxx
Numericsensor[NumericSensorElementName]going
high(uppercritical)hasasserted.(SysBrd12V)
Yes
806f0021-2201xxxx
Faultinslot[PhysicalConnectorSystemElementName]on
system[ComputerSystemElementName].(NoOpROM
Space)
Yes
806f0021-2582xxxx
Faultinslot[PhysicalConnectorSystemElementName]on
system[ComputerSystemElementName].(AllPCIError)
Yes
806f0021-3001xxxx
Faultinslot[PhysicalConnectorSystemElementName]on
system[ComputerSystemElementName].(PCI1)
Yes
806f0108-0a01xxxx
[PowerSupplyElementName]hasFailed.(PowerSupply1)
Yes
806f0108-0a02xxxx
[PowerSupplyElementName]hasFailed.(PowerSupply2)
Yes
806f010c-2001xxxxUncorrectableerrordetectedfor
[PhysicalMemoryElementName]onSubsystem
[MemoryElementName].(DIMM1)
Yes
296Systemx3500M5InstallationandServiceGuide

Table of Contents

Related product manuals