166-904-001:IMMI2CTestFailed
IMMIndicatesfailureinPCA9557--I2CI/OExpanderbus(BUS3).
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Performtheactionsmentionedoneatatimeandtrythetestaftereachaction:
1.Turnoffthesystemanddisconnectitfrompower.Waitfor45seconds.Reconnectittopower.
2.MakesurethatDSAandBMC/IMMareatthelatestlevel.
3.Runthetestagain.
4.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
LenovoSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
166-905-001:IMMI2CTestFailed
IMMIndicatesfailureinPSU1bus(BUS4).
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Performtheactionsmentionedoneatatimeandtrythetestaftereachaction:
1.Turnoffthesystemanddisconnectitfrompower.Waitfor45seconds.Reconnectittopower.
2.MakesurethatDSAandBMC/IMMareatthelatestlevel.
3.Runthetestagain.
4.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
1190Systemx3500M5InstallationandServiceGuide