24-hoursupportcenter
Automaticerrorretryandrecovery
Automaticrestartonnonmaskableinterrupt(NMI)
Automaticrestartafterapowerfailure
Backupbasicinput/outputsystemswitchingunderthecontroloftheIntegratedManagementModuleII
(IMM2)
Built-inmonitoringforfan,power,temperature,voltage,andpower-supplyredundancy
Cable-presencedetectiononmostconnectors
Chipkillmemoryprotection
Single-devicedatacorrection(SDDC)forx4DRAMtechnologyDIMMs(availableon16GBDIMMsonly).
Ensuresthatdataisavailableonasinglex4DRAMDIMMafterahardfailureofuptotwoDRAMDIMMs.
Onex4DRAMDIMMineachrankisreservedasaspacedevice.
DiagnosticsupportforServeRAIDandEthernetadapters
Errorcodesandmessages
Errorcorrectingcode(ECC)L3cacheandsystemmemory
FullArrayMemoryMirroring(FAMM)redundancy
Hot-swapcoolingfanswithspeed-sensingcapability
Hot-swapharddiskdrives
Hot-swappowersupplies
InformationandlightpathdiagnosticsLEDpanels
IntegratedManagementModuleII(IMM2)
LightpathdiagnosticsLEDsforDIMMs,microprocessors,harddiskdrives,solidstatedrives,power
supplies,andfans
Memorymirroringandmemorysparingsupport
Memoryerrorcorrectingcodeandparitytest
Memorydownsizing(non-mirroredmemory).Afterarestartoftheserverafterthememorycontroller
detectsanon-mirroreduncorrectableerrorandthememorycontrollercannotrecoveroperationally,the
IMM2.1logstheuncorrectableerrorandinformsPOST.POSTlogicallymapsoutthememorywiththe
uncorrectableerror,andtheserverrestartswiththeremaininginstalledmemory.
Menu-drivensetup,systemconfiguration,andredundantarrayofindependentdisks(RAID)configuration
programs
Microprocessorbuilt-inself-test(BIST),internalerrorsignalmonitoring,internalthermaltripsignal
monitoring,configurationchecking,andmicroprocessorandvoltageregulatormodulefailureidentification
throughlightpathdiagnostics
Nonmaskableinterrupt(NMI)button
ParitycheckingonthePCIebuses
Powermanagement:compliancewithAdvancedConfigurationandPowerInterface(ACPI)
Power-onself-test(POST)
ProactivePlatformAlerts(includingPredictiveFailureAnalysisandSelf-Monitoring,Analysisand
ReportingTechnologyalerts):microprocessors,voltageregulators,memory,internalstorage(SAS/SATA
harddiskdrivesandsolid-statedrives,NVMesolid-statedrives,M.2storage,flashstorageadapters),
fans,powersupplies,RAIDcontrollers,andserverambientandsub-componenttemperatures
RedundantEthernetcapabilitieswithfailoversupport
Redundanthot-swappowersuppliesandredundanthot-swapfans
Redundantnetworkinterfacecard(NIC)support
Remotesystemproblem-determinationsupport
ROM-baseddiagnostics
ROMchecksums
SerialPresenceDetection(SPD)onmemory,VPDonsystemboard,powersupply,andharddiskdriveor
solidstatedrivebackplanes,microprocessorandmemoryexpansiontray,andEthernetadapters
Single-DIMMisolationofexcessivecorrectableerrorormulti-biterrorbytheUnifiedExtensibleFirmware
Interface(UEFI)
Solid-statedrives
Standbyvoltageforsystems-managementfeaturesandmonitoring
14Systemx3500M5InstallationandServiceGuide