26 Operating manual LH101
Press the 'F' key and keep it pressed until
the display changes.
Release the 'F' key and turn the rotary knob
until you reach this display.
Press the rotary knob; the configuration of
function 1 is displayed.
Turn the rotary knob until the function is
displayed that you want to set to permanent
or temporary operation.
Press the rotary knob to switch between
permanent and temporary operation.
Turn the rotary knob to select the next
function whose configuration you want to
change …
… or end the configuration process by
pressing 'F' …
5.3.3 Configuring the “refresh“ of functions
By “refreshing” functions we mean the following: In defined regular
intervals, the command station sends function information via the track
to all decoders located on the track. This ensures that a decoder does
not “forget” settings, even if the connection between command station
and decoder is interrupted intentionally (due to “dead frogs”) or
unintentionally (due to dirt or a power interruption). For layouts where
many locomotives or decoders are operating simultaneously, it may
make sense to disable this cyclic transmission of individual functions
to decrease the time delay resulting from the total time required for
each transmission (typically 8 mS). This way, you can decide which