Appendix 93
15 Appendix
This appendix contains information that may be of interest to the
advanced user, or that may help you if you experience problems.
15.1 Error messages on the display
The LH101 will display an error message if
you have done something that was not
allowed at that time.
To return to the previous step, press
Here is the list of possible error messages:
While programming or reading out a decoder, a power overload
(short circuit) was detected. The decoder may not be correctly
connected or may be defective.
While programming or reading out a decoder, no information
was detected. The decoder may not be correctly connected to the
programming output of the LZ100/LZV100 command station
(e. g. the digital locomotive may not be placed properly on the
programming track).
DTR/MTR: Locomotive not called up or locomotive address 0
DTR/MTR: Locomotive called up by another device
DTR/MTR: Locomotive already part of another DTR/MTR
DTR/MTR: Locomotive speed not 0
Locomotive cannot be deleted from command station memory
Command station memory full:
Delete one (or several) locomotive addresses from the command
station memory (see section "Deleting locomotive addresses from the
command station memory ").
There is a data processing error in the LZ100/LZV100 command
station. All information about speed, direction and special functions of
the locomotives as well as about the status of points and occupancy
detectors has been deleted. If this error appears repeatedly, the
battery in the LZ100/LZV100 command station may be dead. Please
contact your model railway dealer or Lenz Elektronik for replacement.
The command sent from the manual control to the command station
is not available in its list of commands. The cause is usually a
software version of the command station that does not support this
command.