8400 motec | Software Manual
I/O terminals
User-defined terminal assignment
144 L Firmware ≤ 02.00 - DMS 2.1 EN - 03/2011
Example
Task:
Based on the preset control mode "Terminals 0", the digital input DI2 is used for
activating the quick stop instead of selecting the fixed setpoint 2/3. For this purpose, the
digital input DI2 must not be linked to the bJogSpeed2 input but to the bSetQuickstop input
of the application.
Procedure:
1. Change the setting of the configuration parameter LA_NCtrl: bSetQuickstop (C00701/
3) which represents the logical link of the bSetQuickstop application unit: "0: Not
connected" "12: DigIn_bIn2"
2. Change the setting of the configuration parameter LA_NCtrl: bJogSpeed2 (C00701/7
)
which represents the logical link of the bJogSpeed2 application unit: "12: DigIn_bIn2"
"0: Not connected"
[6-2] Example: Changing the terminal assignment via configuration parameters
Tip!
The example shows that, for each input of the application, the associated
configuration parameter (C00700/x
or C00701/x) is only allowed to contain one
source that you enter.
C00701/17 LA_NCtrl: bRLQCw 1: C_bTrue
C00701/18
LA_NCtrl: bRLQCcw 0: Not connected
C00701/19
LA_NCtrl: bBrkRelease 15: DigIn_bIn5
C00701/20
L_GP_Counter1: bClkUp 0: Not connected
C00701/21
L_GP_Counter1: bClkDown 0: Not connected
C00701/22
L_GP_Counter1: bLoad 0: Not connected
C00701/23
L_GP_DigitalDelay1: bIn 0: Not connected
C00701/24
L_GP_DigitalDelay2: bIn 0: Not connected
C00701/25
LS_WriteParamList: bExecute 0: Not connected
C00701/26
LS_WriteParamList: bSelectWriteValue_1 0: Not connected
C00701/27
Reserved 0: Not connected
C00701/28
L_GP_DigitalLogic1: bIn1 0: Not connected
C00701/29
L_GP_DigitalLogic1: bIn2 0: Not connected
Parameter Info Lenze setting