8400 motec | Software Manual
Basic functions
Parameter change-over
172 L Firmware 02.00 - DMS 2.1 EN - 03/2011
8.1 Parameter change-over
This basic function provides a change-over for up to 16 freely selectable parameters
between two sets with different parameter values.
The parameter list is created in the same way as the user menu is composed, namely by
means of parameterisation. In the »Engineer«, a user-friendly parameterisation dialog
with import and export functions is available for this purpose.
8.1.1 Configuring the list using the »Engineer« parameterisation dialog
In the »Engineer«, a parameterisation dialog is available for user-friendly creation of the
parameter list and entry of the parameter values:
How to open the parameterisation dialog:
1. »Engineer« Go to the Project view and select the 8400 motec controller.
2. Go to Workspace and change to the Application parameters tab.
3. Go to the Overview dialog level and click the Basic functions button.
4. Go to the Overview Basic functions dialog level and click the Parameter change-
over button.
Parameterisation dialog in the »Engineer«