EasyManua.ls Logo

Lenze 8400 motec - Electrical data

Lenze 8400 motec
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware 02.00 - DMS 2.1 EN - 03/2011 L 145
8400 motec | Software Manual
I/O terminals
Electrical data
Related topics:
Application example: Debouncing a digital input
( 341)
Signal flow
( 150)
Interface description
( 154)
Pre-assignment of the drive application
( 163)
6.4 Electrical data
Digital terminals
Terminal Application / electrical data
24E External 24-V voltage supply
DC 19.2 ... 28.8 V, IEC 61131-2, SELV/PELV
Current consumption 0.6 A
In case of polarity reversal: No function and no destruction
GND External reference potential
RFR Controller enable
Electrical data as in digital inputs
DI1 ... DI5 Digital inputs
LOW level: 0 ... +5 V
HIGH level: +15 ... +30 V
Input current: 8 mA per input (at 24 V)
Electric strength of external voltage max. ±30 V, permanent
Input impedance: 3.3 kΩ (2.5 Ω ... 6 kΩ)
Max. input frequency: 10 kHz (DI1/DI2)
Processing cycle: 1 kHz (1 ms)
DO1 Digital output
LOW level: 0 ... +5 V
HIGH level: +15 ... +30 V
Output current: max. 50 mA per output
(external resistance > 480 Ω at 24 V)
Processing cycle: 1 kHz (1 ms)
24O 24-V voltage supply for external sensors
Output current: max. 100 mA
GIO Reference potential (digital ground)
NO / COM Relay output
Potential-free contact (NO contact)
AC 250 V / 3 A
DC 24 V / 2 A ... 240 V / 0.22 A
•not inductive