8400 motec | Software Manual
Parameter reference
Parameter list | C02589
302 L Firmware ≤ 02.00 - DMS 2.1 EN - 03/2011
C02589
C02593
Parameter | Name:
C02589 | Holding brake: Time system
Data type: UNSIGNED_16
Index: 21986
d
= 55E2
h
Operating times of the holding brake
• The electromechanical delay times of the holding brake are specified in the data sheets or on the holding brake
nameplate.
Holding brake control
Setting range (min. value | unit | max. value)
0 ms 60000
Subcodes Lenze setting Info
C02589/1 100 ms Holding brake: Closing time
• Time in which the holding brake is completely applied
from the beginning of control and in which the
controller is inhibited.
C02589/2 100 ms Holding brake: Release time
• Time in which the holding brake is completely
released from the beginning of control.
C02589/3 0 ms Reserved
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C02593 | Holding brake: Activation time
Data type: UNSIGNED_32
Index: 21982
d
= 55DE
h
Time parameter for the delay of trigger signals of the holding brake control
Holding brake control
Setting range (min. value | unit | max. value)
0.0 s 3600.0
Subcodes Lenze setting Info
C02593/1 0.0 s Holding brake: Actual value monitoring
• Time in which the actual value shall have reached the
threshold for brake application when the setpoint has
already reached the threshold.
• Time > 0 s: If the actual speed value has not reached
the threshold within the time for brake application,
the holding brake is applied by control.
• Time = 0 s: The brake is only applied by control when
the actual speed has reached the application
threshold.
C02593/2 0.0 s Holding brake: Application delay
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000