Firmware ≤ 02.00 - DMS 2.1 EN - 03/2011 L 201
8400 motec | Software Manual
Diagnostics & error management
Monitoring
 
9.5.2 Setting the error response
When a monitoring function responds, the response set for this monitoring function
(Trouble, Fault, etc.) will be triggered.
 For many monitoring functions the response can be individually parameterised via 
parameters.
 Tip!
The table in chapter "Short overview (A-Z)
" contains the error messages for which
the response can be set  .
 ( 208) 
Warning thresholds
Some of the monitoring functions are activated if a defined warning threshold has been
exceeded.
 The corresponding preset threshold values can be changed via the following 
parameters:
Parameter Info Lenze setting
Value Unit
C00120 Motor overload threshold (I²xt) 100 %
C00123
Device utilisat. threshold (Ixt) 100 %
C00909/1
Max. positive speed 120 %
C00909/2
Max. negative speed 120 %
C00910/1
Max. positive output frequency 300 Hz
C00910/2
Max. negative output frequency 300 Hz