Firmware ≤ 02.00 - DMS 2.1 EN - 03/2011 L 21
8400 motec | Software Manual
Commissioning
LED status display
3.2 LED status display
Tip!
Information on failures can be transmitted e.g. to a master control via the fieldbus.
Information on some operating states can be
quickly obtained via the two-colored LED display on
the top of the device.
The meaning can be seen from the table below.
green
"DRIVE READY"
red
"DRIVE ERROR"
Description Device state
(Display in C00137
)
Off Off OFF or initialisation active Init
Off Safe torque off is active SafeTorqueOff
Off Device is ready to start ReadyToSwitchON
Off Device is switched on SwitchedON
Off Motor data identification/operation OperationEnabled
The controller is ready to switch on, switched
on or the operation is enabled and a warning
is indicated.
Off Trouble is active Trouble
Off Fault is active Fault
Legend
The symbols used for indicating the LED states have the following meaning:
LED is flashing once approx. every 3 seconds (slow flash)
LED is flashing once approx. every 1.25 seconds (flash)
LED is flashing twice approx. every 1.25 seconds (double flash)
LED is blinking every second
LED is permanently on
Detailed information on diagnostics using the »Engineer« and a description of
possible error messages can be found in the chapter entitled "Diagnostics &
error management". ( 193)