L_GP_DigitalDelay2
342 L Firmware 02.00 - DMS 2.1 EN - 03/2011
12.8 L_GP_DigitalDelay2
This FB delays binary signals.
ON and OFF delay can be parameterised separately.
Inputs
Outputs
Parameter
Identifier
Data type
Information/possible settings
bIn
BOOL
Input signal
Identifier
Data type
Value/meaning
bOut
BOOL
Output signal (time-delayed input signal)
Parameter Possible settings Info
C00721/1
0.0 s 3600.0 ON delay
Lenze setting: 0.0 s
C00721/2
0.0 s 3600.0 OFF delay
Lenze setting: 0.0 s
For a detailed functional description see L_GP_DigitalDelay1.
/B*3B'LJLWDO'HOD\
E,Q
E2XW
& &
,Q
2XW
&
&RQILJXUDWLRQSDUDPHWHU
/B*3B'LJLWDO'HOD\BE2XW
(QWU\LQVHOHFWOLVW

Table of Contents

Other manuals for Lenze 8400 motec

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 motec and is the answer not in the manual?

Lenze 8400 motec Specifications

General IconGeneral
Input Voltage3-phase 380V to 480V AC
Control ModeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, short-circuit, overtemperature