Firmware 02.00 - DMS 2.1 EN - 03/2011 L 207
8400 motec | Software Manual
Diagnostics & error management
Error messages of the operating system
9.7.2 Reset of error message
An error message with the response "Fault", "Trouble", or "Warning locked" must be
explicitly reset (acknowledged) after the cause of the error has been eliminated.
To reset (acknowledge) a pending error message, execute the controller command
C00002/19
="1".
Tip!
With an online connection to the controller, use the Diagnostics tab of the
»Engineer« and click Error message reset to reset a pending error message.

Table of Contents

Other manuals for Lenze 8400 motec

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 motec and is the answer not in the manual?

Lenze 8400 motec Specifications

General IconGeneral
Input Voltage3-phase 380V to 480V AC
Control ModeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, short-circuit, overtemperature
Relative Humidity≤ 95 %, no condensation
AltitudeUp to 1000m above sea level
Storage Temperature-20°C to 65°C