Firmware 02.00 - DMS 2.1 EN - 03/2011 L 35
8400 motec | Software Manual
Device control (DCTRL)
Device commands (C00002/x)
4.1.1 Load Lenze setting
The C00002/1
= "1: On / start" device command resets the parameters to the Lenze setting
which are saved in the controller Firmware.
Can only be executed if the controller is inhibited; otherwise, the feedback C00002/
1 = "6: No access - controller inhibit" will be returned.
All parameter changes which have been carried out after the last time the parameter
set was saved will be lost!
This controller command has an effect on the settings of the parameters of the
operating system, application and module.
How to load the Lenze setting:
1. If the controller is enabled, it must be inhibited, e.g. by executing the "Enable/
Inhibit controller" device command (C00002/16
= "0: Off / ready").
2. Execute the "Load Lenze setting" device command:
C00002/1
= "1: On / start"
The load process may take a couple of seconds. After the device command has been
called in C00002/1
, a dynamic status information ("Work in progress" "Off /
Ready") is returned.

Table of Contents

Other manuals for Lenze 8400 motec

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 motec and is the answer not in the manual?

Lenze 8400 motec Specifications

General IconGeneral
Input Voltage3-phase 380V to 480V AC
Control ModeVector control
CommunicationCANopen, PROFIBUS, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, short-circuit, overtemperature
Relative Humidity≤ 95 %, no condensation
AltitudeUp to 1000m above sea level
Storage Temperature-20°C to 65°C

Related product manuals