171
INSTALLER SETTING
170
INSTALLER SETTING
ENGLISH
Air conditioner Fan operation interlocked with ventilation setting
(air conditioner)
It is the function to set the air conditioner fan operation if the ventilation is operated while the air
conditioner operation is stopped when the air conditioner and the ventilation are installed to
interface with each other.
• You can set the following setting values using [<,>(left/right)] button.
- When the air conditioner operation is Off, if the ventilation product is in operation, the air
conditioner fan shall be operated, and when the fan is in operation, dust may fall, so it is the
function to set the air conditioner fan operation status in case of ventilation interface through
the setting.
Value Description
Off The air conditioner indoor unit Fan is Off during the ventilation interface
On
The air conditioner indoor unit operates in very weak wind during the
ventilation interface
Indoor unit Auto-Start setting (air conditioner / DX ventilator)
It is a function that sets whether to restore the indoor unit operation by resuming the previous
power-on state or as power-off state in the power failure compensation.
• You can set the following setting values using [<,>(left/right)] button.
Value Description
Use Use indoor unit auto restart
Not use Not use indoor unit auto restart