Maintenance work on the carrier
7.5 Exhaust system with exhaust emission control
7 - 38 3 302 364 en Maintenance manual
GMK 4100L-1
25.11.2016
• Use only the suitable filter cartridge; à Replacing the filter cartridge of the
compressed air drier
, p. 7 - 95.
S
Risk of damage to the pump unit.
Oil from the compressed air system can damage the pump unit.
Therefore, a filter cartridge must be installed in the compressed air drier
that removes both water and oil.
Manitowoc Crane Care recommends the
suitable filter cartridge with the GROVE part number 04157844.