Maintenance work on the superstructure
8.12 Electrical system
8 - 74 3 302 364 en Maintenance manual
GMK 4100L-1
25.11.2016
Have faulty lamps in the spotlights replaced only by qualified personnel.
8.12.2 Have the battery on the electronics board replaced
Spare parts
and tools
Prerequisites The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
Changing
Open the cover (1) behind the seat in the
crane cab.
Changing the battery (2) on the electronics
board (3).
Close the cover.
Check the correct operation of all controls.
G
Risk of accidents from exploding glass bodies and high voltage.
The glass bodies of gas discharge lamps (xenon lights) are pressurised.
If the la
mp breaks, the glass splinters explosively and shards scatter.
Xenon lights operate at high voltage. While changing the lamp, there is
still a dange
r of residual voltage discharging (electric shock) even when
the battery master switch is switched off.
Have faulty lamps replaced only by properly qualified personnel who use
the relevant protective equipment.
Y 10
Designation Quantity GROVE part no.
Lithium battery 3.6 V 1 03143172