7.19.3 Checking the cotter pin
Prerequisites The coupling must be closed; à p. 7 - 132.
Checking the
cotter pin
Check the wear on the cotter pin (1). The
diameter of the crowned section (arrows)
must not be less than the following values:
If the dimension is smaller than that given
above, have the cotter pin replaced by
Manitowoc Crane Care or an authorised GROVE
dealer or your qualified repair crew.
Also check the cotter pin for the correct
vertical play. Take a screwdriver and press
the pin (1) upwards. The vertical play (2) of
the pin must not exceed 4 mm (0.15 in).
M 3
Model series 400: 36.5 mm (1.44 in)
Model series 700: 46.0 mm (1.81 in)