EasyManua.ls Logo

Manitowoc Grove GMK 4100L-1 - Longer out of Service Periods

Manitowoc Grove GMK 4100L-1
356 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Longer out of service periods
25.11.2016
Maintenance manual 3 302 364 en 9 - 1
GMK 4100L-1
9 Longer out of service periods
Carry out the following jobs if the truck crane is going to be out of service
for a long period (months).
Putting the truck
crane ou
t of
service
Clean the truck crane thoroughly on the inside and outside.
Remove any rust and touch up the paintwork.
Parts that are not painted must be lubricated with an acid-free grease
or oil.
If more than half of the oil change interval has passed:
Change the oil according to the maintenance plans M 3 to M 12.
Seal the air filter.
Increase the tyre pressure by 10% and mark the tyre positioning, or
support the truck crane and leave it standing on the outriggers.
Observe the specifications on preservation in the Engine manufacturer’s
documentation
.
Checks
Check the level in the fuel tanks. Always keep the tanks filled.
Check the batteries every week and recharge them if necessary.
Check the tyre pressure every week and correct it if necessary.
Perform a full functional test on the truck crane every two weeks.
(Open the air filter beforehand).
Run the hydraulic systems up to a fluid temperature of approx. 50 °C
(122 °F) and then check all functions of the carrier and superstructure
hydraulic systems.
s

Table of Contents