Maintenance work on the carrier
7.15 Hydraulic system
25.11.2016
Maintenance manual 3 302 364 en 7 - 101
GMK 4100L-1
7.15.5 Changing the ventilation filter
Reducing the
interval
Under difficult operating conditions – at extremely sandy or dusty
locations – you must change the ventilation filters earlier than normal.
Spare parts
and t
ools
Prerequisites The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
Change the filter (1).
M 12
Designation Quantity GROVE part no.
Filter 1 01576026
O
Risk of damage to the environment from filter residues
Store used hydraulic oil filter inserts in suitable receptacles and have them
disposed of properly by qualified personnel.