Maintenance work on the carrier
7.8 Angle gear
7 - 54 3 302 364 en Maintenance manual
GMK 4100L-1
25.11.2016
• Remove the screw (1) from the oil cooler (2).
• Fill the oil up to the lower edge of the
opening (1).
• If necessary fit a new gasket and tighten
the screw (1).
(A) – angle gear without hydraulic
drive (standard configuration).
(B) – angle gear with hydraulic drive
(additional equipment
Driving from the
crane cab
).
• Fill the oil up to the lower edge of the
opening (1).
• Fit a new gasket and tighten the drain plug
(1).
Checks after the
oil change
In order to circulate the oil around the oil circuit you must try out operation
of a hy
draulic function on the superstructure (for instance tilting the
crane cab).
• Switch the engine off and wait for about 5 minutes.
• Check the oil level; à p. 7 - 50.
• Check the angle gear, the filter and the oil cooler for leaks.