Maintenance work on the carrier
7.15 Hydraulic system
25.11.2016
Maintenance manual 3 302 364 en 7 - 113
GMK 4100L-1
Changing filters 3
and 4
• Remove the receptacle (1).
• Place the filter in a receptacle.
• Change the filter (2).
• Replace any defective parts, where
necessary.
• Fill the receptacle with clean oil.
• Put the receptacle on and tighten it.
• Change the filter on the opposite side in the
same way.
O
Risk of damage to the environment from filter residues
Store used hydraulic oil filter inserts in suitable receptacles and have them
disposed of properly by qualified personnel.