Maintenance overview
5.1 Maintenance intervals
5 - 2 3 302 719 en Maintenance manual
GMK6300L-1
13.02.2018
The maintenance interval which occurs first determines when the next
maintenance is due.
–The driven km (or mi) can be taken from the speedometer.
– You can call up the engine and
power unit operating hours (oper. hrs.)
of the superstructure one by one on the
ECOS display in the crane cab.
The operating hours of the engine are equivalent to the total operating
hours of the superstructure.
The following table sets out the maintenance intervals for the maintenance
plans:
Please note that the long-term maintenance plans always include the
short-term ones.
Maintenance
plans
Maintenance
interval
Driven km (mi)
(carrier)
Operating hours
(oper. hrs.) of the
engine
(super
structure)
D
daily/before
putting into
o
peration
— —
W weekly — —
M 1 monthly
approx. 2000
(approx. 124
0)
approx. 100
M 3
every three
months
5,000 – 6,000
(3
,10
0 – 3,730)
250
M 6
every six
months
10,000 – 12,500
(6
,21
0 – 7,770)
500
M 12
every
12 months
20,000 – 25,000
(1
2,430
– 15,530)
1,000
Y 2
every
24 months
40,000 – 50,000
(2
5,000
– 31,000)
2,000
Y 3
every
36 months
— 3,000
Y 5
every
60 months
100,000
(62,00
0)
5,000
Y 6
e
very
72 months
— 6,000
Y 10
every
120
months
20
0,000
(124,000)
12,000

Table of Contents

Other manuals for Manitowoc Grove GMK6300L-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK6300L-1 and is the answer not in the manual?

Manitowoc Grove GMK6300L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK6300L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals