9-10
Published 01-29-2014, Control # 496-00
LUBRICATION TMS800E SERVICE MANUAL
top. If the “milky” appearance was due to air
foaming, it will dissipate and the oil should closely
match the fresh oil. Should you have any
questions, please contact your local Grove
distributor or Manitowoc Crane Care.
23. Hydraulic Reservoir
Lube Type - HYDO
Lube Interval - Check fluid level every 10 hours or daily,
using sight gauge on side of tank, with boom down and
retracted and all outrigger cylinders retracted; drain and
refill as necessary. Replace oil every 2000 hours or 2
years, whichever interval occurs first.
NOTE: After 2000 hours or 2 years of service, an oil
sample should be taken and laboratory analyzed. If
it continues to meet a minimum cleanliness level of
ISO 16/13, the service interval can be increased to
3000 hours or 3 years.
Lube Amount - 656.6 l (173.5 gal) (tank only), to the
FULL mark on sight gauge.
Application - Fill through filler cap on top of tank. When
tank is drained, clean the magnetic pipe plug.
Replace breather every 500 hours or 6 months,
whichever interval occurs first.
24. Hydraulic Filter
Check filter every 500 hours or 6 months, whichever
interval occurs first.
Change the filter when the indicator is red.
25. Fuel Filter
Drain water trap every 10 hours or daily and change filter
every 500 hours or 6 months.
26. Air Cleaner Filter
Replace air cleaner filter element when indicator shows
red (25” H2O).
27. Coolant Strainer (Superstructure Cab Heater)
Close the shutoff valves. Unscrew the hex plug and
clean the strainer screen after first 100 hours and every
2000 hours or 12 months thereafter.
28. Not used.
SUPERSTRUCTURE LUBRICATION
29. Turntable Gear Box
Lube Type - SSGL-5
Lube Interval - Check and fill every 50 hours. Drain and
fill after first 250 hours and every 500 hours or 12
months thereafter, whichever interval occurs first.
Lube Amount -5.4 l (1.4 gal)
Application - Fill until oil level is at top of sight gauge
30. Turntable Gear and Drive Pinion
Lube Type - OGL
Lube Interval - 500 hours or 6 months, whichever
interval occurs first
Lube Amount - Coat all teeth
Application - Spray on; 2 places
31. Turntable Bearing
Lube Type - EP-MPG
Lube Interval - 500 hours or 6 months, whichever
interval occurs first
Lube Amount - Until grease extrudes the whole
circumference of the bearing.
Application - 2 grease fittings. Rotate the turntable 90°
and apply grease to fittings. Continue rotating 90° and
grease the fittings until the whole bearing is greased.
32. Main Hoist
Lube Type - AGMA EP-4
Lube Interval - Check and fill every 1000 hours or 12
months, whichever interval occurs first. Drain and fill
annually.
Lube Amount - Capacity - 14.7 l (15.5 qt)
Application - Fill until level with the check plug opening.
33. Auxiliary Hoist
Lube Type - AGMA EP-4
Lube Interval - Check and fill every 1000 hours or 12
months, whichever interval occurs first. Drain and fill
annually.
Lube Amount - Capacity - 14.7 l (15.5 qt)
Application - Fill until level with the check plug opening.
Reference Only