J.). Arrange windows so you can view the EPROM
window & Output Window values
2. Set swing brake center percentage X & Y counts to 500.
Attach test fitting and pressure gage GP4 (see in figure
#1) port with engine running at idle. Fully depress swing
brake pedal. Monitor the pressure gauge and adjust the
swing brake solenoid Max counts to reach 16.9 bar (245
psi). Then raise the counts up to reach 17.2 bar (250
psi).To set swing brake solenoid threshold. Slowly
depress swing brake pedal down until you reach 1.7 bar
(25 psi) on the gauge. Then looking at the swing brake
output value, set the swing brake solenoid threshold 5
counts lower than the output value.