WINTEST - Issue 5.a
GUF513.13
AUTOTRONIC 5 - PowerShuttle - Error codes
TR11: PTO solenoid valve
Description
Location: on the right-hand hydraulic cover (Fig. 8)
ON/OFF solenoid valve controlled by frequency carrier
signal.
- Connectors 1: Signal
- Connectors 2: Ground
Signals:
OFF solenoid valve: 0A
ON solenoid valve: 12V
Possible error codes
TR11
MA-11-01267A
Fig. 8
MA-11-01266A
1
2
1
2
Fig. 9
Errors Description
Reaction of the
System
Solutions
Resetting the system
after clearing error
207 Short circuit at +12V
PTO locked
Check:
- Contacts
- Harness connections
-Wiring
-F6 fuse
Press the clutch pedal to
contact the BOCor:
move the PTO switch
from ON to OFF
208 Short circuit at 0V
209 Open circuit
211 Switch ON and PTO inactive Move the PTO switch
from ON to OFF