Communication
> Devices with LTE (4G) module (MDH 862 EU, MDH 866 EU); hardware version: HW 03
Target region Europe
GSM/GPRS/EDGE 900 (B8), 1800 (B3) MHz; max. 236 kbps
HSxPA 900 (B8), 2100 (B1) MHz; downlink max. 42 Mbps, uplink max. 5,76 Mbps
LTE 800 (B20), 900 (B8),1800 (B3), 2100 (B1), 2600 (B7) MHz; downlink max. 150 Mbps, uplink
max. 50 Mbps
Transmission output
power
CLass 3 (0.2 W, 23 dBm) @ LTE; CLass 3 (0.25 W, 23 dBm) @ 3G
Class 4 (2 W) @ GSM 900; Class 1 (1 W) @ DCS 1800
TAC 35162207
.
> Devices with LTE (4G) module (MDH 862 EU, MDH 866 EU); hardware version: HW 04
Target region EMEA
GSM/GPRS/EDGE 900 (B8), 1800 (B3) MHz; max. 236 kbps
HSxPA 900 (B8), 1800 (B3), 2100 (B1) MHz; Downlink max. 42 Mbps, Uplink max. 5,76 Mbps
LTE 800 (B20), 900 (B8),1800 (B3), 2100 (B1), 2600 (B7), 700 (B28A) MHz;
Downlink max. 150 Mbps, Uplink max. 50 Mbps
RF parameters
Output power - typical values for max output level
2G:
LB: 33 dBm; HB: 30 dBm
3G/TD-SCDMA: 24dBm
4G (FDD & TDD): 23dBm @1RB
Sensitivity - typical sensitivity levels
-108 dBm @ 2G
-113.5 dBm @ 3G
-103 dBm @ 4G FDD (BW=5 MHz)
Antenna connector
2 pieces SMA socket
TAC 35162610
.